Bleeding Air From The Injectors; Electrical System Maintenance; Servicing The Battery - Toro 30381 Operator's Manual

Traction unit
Hide thumbs Also See for 30381:
Table of Contents

Advertisement

Bleeding Air from the Injectors

Note: Use this procedure only if the fuel system has been
purged of air through normal priming procedures and engine
will not start; refer to Bleeding the Fuel System (page 49).
1. Place a rag under the pipe connection coming from
the injection pump to the No. 1 injector nozzle as
illustrated in Figure 69.
Figure 69
1. Pipe connection from the injection pump to the No. 1
injector nozzle
2. Move the throttle to the Fast position.
3. Turn the ignition key the Start position, and watch the
fuel flow around the connector.
CAUTION
The engine may start during this procedure.
Moving fans and belts in a running engine can
severely injure you or bystanders.
Keep hands, fingers, loose clothing/jewelry,
and hair away from the engine fan and belt
during this procedure.
4. Tighten the pipe connector securely when it attains a
solid flow.
5. Turn the key to the Off position.
6. Repeat this procedure for the remaining nozzles.
Electrical System
Maintenance
Important: Whenever working with the electrical
system, always disconnect the battery cables, negative
(-) cable first, to prevent possible wiring damage from
short-outs.

Servicing the Battery

Service Interval: Every 50 hours
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead compounds,
chemicals known to the State of California
to cause cancer and reproductive harm.
Wash hands after handling.
Keep the top of the battery clean. If you store the machine in
a location where temperatures are extremely high, the battery
will run down more rapidly than if the machine is stored in a
location where the temperature is cool.
Keep the top of the battery clean by washing it periodically
with a brush dipped in ammonia or bicarbonate of soda
solution. Flush the top surface with water after cleaning it.
Do not remove the fill caps while cleaning the battery.
The battery cables must be tight on the terminals to provide
good electrical contact.
If corrosion occurs at the terminals, disconnect the cables,
negative (-) cable first, and scrape the clamps and terminals
separately. Connect the cables, positive (+) cable first, and
coat the terminals with petroleum jelly.
WARNING
Battery terminals or metal tools could short against
metal machine components causing sparks. Sparks
can cause the battery gasses to explode, resulting
in personal injury.
• When removing or installing the battery, do not
allow the battery terminals to touch any metal
parts of the machine.
• Do not allow metal tools to short between
the battery terminals and metal parts of the
machine.