8

Technical data

Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1

Taurus 351 Synergic S MM FDG

Setting range for welding current
Setting range for welding voltage
Duty cycle at 40 °C (100% DC)
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Maximum connected load
Recommended generator rating
cos/efficiency
Insulation class/protection classification
Ambient temperature
Machine/torch cooling
Welding lead
Dimensions L x W x H in mm
Weight
EMC class
Constructed to standard
099-005341-EW501
27.01.2016
Taurus 351 Synergic S MM FDG
MMA
5 A -350 A
20,2 V - 34,0 V
20,2 V - 34,0 V
350 A
10 min (60% DC  6 min. welding, 4 min. pause)
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 25 A
H07RN-F4G6
15 kVA
10,6 kVA
20,3 kVA
0,99 / 90%
H/IP 23
-25 °C to +40 °C
Fan/Gas
70 mm²
1100 x 455 x 1000
107 kg
IEC 60974-1, -10 /
Technical data
TIG
MIG/MAG
20,2 V - 34,0 V
79 V
13,9 kVA
A
/
45