Technical data

Taurus 451 Synergic S MM FDG

8.6
Taurus 451 Synergic S MM FDG
Setting range welding current
Setting range welding voltage
Duty cycle at 40 °C (80 % DC)
Duty cycle at 40 °C (100 % DC)
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Maximum connected load
Recommended generator rating
Cos/efficiency
Insulation class/protection classification
Ambient temperature
Machine/torch cooling
Workpiece lead
Dimensions L x W x H in mm
Weight
EMC class
Constructed to standards
50
MMA
TIG
5 to 450 A
20,2 to 38 V
10,2 to 28,0 V
450 A
420 A
10 min. (60% DC  6 min. welding, 4 min. break)
79 V
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 25 A
H07RN-F4G6
21,6 kVA
15,9 kVA
29,2 kVA
0.99 / 90 %
H/IP 23
-25 °C to +40 °C
Fan / gas
70 mm
1100 x 455 x 1000
118 kg
IEC 60974-1, -10 /
MIG/MAG
14,3 to 36,5 V
20,7 kVA
2
A
/
099-005341-EW501
27.01.2016

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Taurus 351 and is the answer not in the manual?

This manual is also suitable for:

Taurus 551