Fire Control Panel MAG8 - Installation and Operation Manual
Guarantee ....................................................................................................................3
1. Using the MAG8 controls .......................................................................................4
1.1 MAG8 Operation Modes .............................................................................5
1.2 LED Indication for the Status of the Zones (1-8) .........................................5
1.4 LED Indication for the System Status .........................................................6
1.5 Buttons for Programming and Operation ....................................................6
1.6 Switch for Changing the Access Levels ......................................................6
2. Installing the MAG8 Panel .....................................................................................7
3. Initial Power-up of MAG8 Panel ............................................................................8
4. Connecting the Zone Circuits ...............................................................................8
5. Connecting the sounders Circuits .......................................................................9
6. Connecting FAULT and FIRE Relay Circuits ........................................................9
7. Class Change Function ........................................................................................10
8. Connecting of Repeater Panel ............................................................................10
9. Programming Master Panel Mode.......................................................................10
10. Programming Repeater Panel Mode .................................................................10
11. Programming single Panel Mode......................................................................10
12. Programming Wireless Receiver Mode ............................................................11
13. sounder Delay Mode ..........................................................................................11
14. Double Action Mode ...........................................................................................11
15. Instant Action Mode ...........................................................................................11
16. Operating Instructions .......................................................................................13
16.1 Sound Signalization ................................................................................13
16.2 Service Modes ........................................................................................13
17. Connection Diagram ..........................................................................................16
18. Technical Specifications ....................................................................................17
FIRE ALARM RECORD .............................................................................................18
sERvICE RECORD ...................................................................................................18
FIRE ALARM EvENT LOG ........................................................................................19
sPARE PARTs KIT ....................................................................................................19
The system has to be installed by a qualified person to the latest Fire Alarm and Installation
Regulations which are mandatory in the applicable country of installation.
Before commencing the installation of this Fire Alarm Panel, ensure it is sited in a position, which
is visible to the Fire Brigade when entering the premises, and where ease of access is provided
for users and service engineers. Space must be available to easily open external and internal
doors.
The Electrical Supply to the panel must be isolated and must not be capable of being accidentally
switched off. A 'Lockable Switch fuse Unit' positioned within 2 meters of the panel should be
clearly labelled FIRE ALARM - DO NOT SWITCH OFF.
EN 54-2/4 compatible panels.
All specifications are subject to change without notice.