DC Reactor
A DC Reactor is used to control harmonics generated by the Inverter. It is more effective than and can be used
in combination with an AC Reactor. It is also used to increase the power factor.
Models and Application
The standard models of DC Reactors are listed below.
Inverter
Voltage
Class
200-V Class
400-V Class
-18
9
Max. Appli-
cable Motor
Model No.
Capacity
(kW)
0.4/0.75
3G3HV-PUZDAB5.4A8MH
1.5 to 3.7
3G3HV-PUZDAB18A3MH
5.5/7.5
3G3HV-PUZDAB36A1MH
3G3HV-
11/15
PUZDAB72A0.5MH
3G3HV-
18.5
PUZDAB90A0.4MH
3G3HV-
0.4/0.75
PUZDAB3.2A28MH
3G3HV-
1.5 to 2.2
PUZDAB5.7A11MH
3G3HV-
3.7
PUZDAB12A6.3MH
3G3HV-
5.5/7.5
PUZDAB23A3.6MH
3G3HV-
11/15
PUZDAB33A1.9MH
3G3HV-
18.5
PUZDAB47A1.3MH
DC Reactor
Rated
Rated
Inductance
Voltage
Current
(mH)
(V)
(A)
5.4
8
18
3
36
1
DC800
72
0.5
90
0.4
3.2
28
5.7
11
12
6.3
DC800
23
3.6
33
1.9
47
1.3
Loss
(W)
8
18
22
29
45
9
11
16
27
26
42