Omron I537-E2-01 User Manual page 123

Table of Contents

Advertisement

Param-
eter-
Number
Output termi-
nal status
U1-11
Output Term
Operation sta-
U1-12
Int Ctl Sts 1
Cumulative
operation time
U1-13
Elapsed Time
Software No.
(flash mem-
U1-14
FLASH ID
Terminal A1
input voltage
U1-15
Term A1 Level
Terminal A2
input voltage
U1-16
Term A2 Level
Motor second-
ary current
U1-18
Mot Sec Cur-
Output fre-
quency after
soft-starter
(SFS output)
U1-20
SFS Output
-38
5
Name
Description
LCD
Display
Shows output ON/OFF status.
1: Multi-function
contact output 1
(M1-M2) is ON
1: Multi-function
contact output 2
(M3-M4) is ON
Not used
(Always 0)
Not used
(Always 0).
Sts
1: Error output
(MA/AB-MC) is
ON
Inverter operating status.
Run
tus
1: Zero speed
1: everse
1: Reset signal
input
1: Speed agree
1: Inverter ready
1: Minor fault
1: Major fault
Monitors the total operating time
of the Inverter.
The initial value and the operat-
ing time/power ON time selection
can be set in o2-07 and o2-08.
(Manufacturer's ID number)
ory)
Monitors the input voltage of the
voltage frequency reference. An
input of 10 V corresponds to
100%.
Monitors the input voltage of the
multi-function analog input.
An input of 10 V corresponds to
100%.
Monitors the calculated value of
the motor secondary current.
(Iq)
The motor rated secondary cur-
rent corresponds to 100%.
rent
Monitors the output frequency
after the soft starter.
The frequency given does not
include compensations.
The unit is set in o1-03.
Output Signal Level During Multi-
Min.
Function Analog Output
Unit
(Cannot be output.)
(Cannot be output.)
0
(Cannot be output.)
hr
(Cannot be output.)
10 V: 100% (10 V)
0.0%
(0 to + 10 V possible)
10 V: 100% (10 V)
0.0%
(0 to +10 V possible)
10 V:Motor rated secon-
dary current)
0.0%
(0 to +10 V output)
10 V: Max. frequency
0.00
(0 to + 10 V possible)
Hz
RS-422A/
Access
485
Level
Register
-
A
4AH
-
A
4BH
A
4CH
-
A
4DH
A
4EH
A
4FH
A
51H
A
53H

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents