6
DSC OPERATION
■ Transmitting DSC Calls (Continued)
D Test call
Testing on the exclusive DSC distress and safety calling
channels should be avoided as much as possible by using
other methods. When testing on the distress/safety channel
is unavoidable, it should be indicated that these are test
transmissions.
Normally the test call would require no further
communications between the two stations involved.
q Enter "Test Call" in the DSC menu.
DSC Menu
(Push [MENU])
w Rotate [SELECTOR] to select a desired preset Individual
address or "Manual Input," then push [ENT].
• The ID code for the individual can be set first. (p. 16)
• When "
Manual Input
to set the 9 digit MMSI ID code for the individual you wish to
call.
5GNGEV #FFTGUU
/CPWCN +PRWV
,QJP
2CWN
)GQTIG
%.4 'ZKV  '06 1-
32
Test Call
(Rotate [SELECTOR], then push [ENT].)
" is selected, push the keypad keys
&5% /GPW
e After step w, "Test Call Ready" is displayed.
&5% /GPW
6GUV %CNN 4GCF[
%.4 'ZKV  '06 1-
r Push [ENT] to transmit the Test call.
• If Channel 70 is busy, the transceiver stands by until the
channel becomes clear.
6GUV %CNN
t After the Test call has been transmitted, the display
automatically returns to the previous screen (before you
entered the DSC menu).