Error Name/Error Condition/Major Cause/Solution
TD sensor output error: Upper Limit (K)
TD sensor output error: Upper Limit (C)
TD sensor output error: Upper Limit (M)
TD sensor output error: Upper Limit (Y)
TD sensor output: Vt (SP3-210-001 to 004) > output upper limit error
threshold (SP3-211-002) continuously exceeded the upper limit
occurrence threshold value (SP3-211-003).
TD sensor connector dropout (connection fault)
1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness
(disconnection, etc.)
3. If the sensor is defective, replace the development unit.
Error Name/Error Condition/Major Cause/Solution
TD sensor output error: Lower limit (K)
TD sensor output error: Lower limit (C)
TD sensor output error: Lower limit (M)
TD sensor output error: Lower limit (Y)
TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error
threshold (SP3-211-004) is continuously below the lower limit
occurrence threshold value (SP3-211-005)
TD sensor connector missing/dropout
1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness
(disconnection, etc.)
3. If the sensor is defective, replace the development unit.
Error Name/Error Condition/Major Cause/Solution
TM (ID) sensor calibration error (F)
Service Call 324-396