SC No.
Level
Error Name/Error Condition/Major Cause/Solution
• The HDD is connected but the driver detected the following errors.
• SS_NOT_READY:/* (-2)HDD does not become READY*/
• SS_BAD_LABEL:/* (-4)Wrong partition type*/
• SS_READ_ERROR:/* (-5)Error occurred while reading or
checking the label*/
• SS_WRITE_ERROR:/* (-6)Error occurred while writing or
checking the label*/
• SS_FS_ERROR:/* (-7)Failed to repair the filesystem*/
• SS_MOUNT_ERROR:/* (-8)Failed to mount the filesystem*/
• SS_COMMAND_ERROR:/* (-9)Drive not responding to
command*/
• SS_KERNEL_ERROR:/* (-10)Internal kernel error*/
• SS_SIZE_ERROR:/* (-11)Drive size too small*/
• SS_NO_PARTITION:/* (-12)The specified partition does not
exist*/
• SS_NO_FILE:/* (-13)Device file does not exist*/
• Attempted to acquire HDD status through the driver but there has
been no response for 30 seconds or more.
• Unformatted HDD
• Label data corrupted
• HDD defective
Format the HDD through SP mode.
Service Call 816-899