Ricoh MET-C1 Field Service Manual page 551

Table of Contents

Advertisement

SC No.
Level
SC No.
Level
SC781-01
D
SC No.
Level
SC791-00
D
Error Name/Error Condition/Major Cause/Solution
When original source of 5V power supply is ON, protection device
intercept of 24V power system is detected.
In 24V power supply system:
• Motor defective
• Solenoid defective
• Harness short- circuit
• Replace the PCB
• Replace the short-circuited part (harness, motor, solenoid)
Error Name/Error Condition/Major Cause/Solution
Bank 2 (Lower optional paper tray) Protection Device Intercept Error
When original source of 5V power supply is ON, protection device
intercept of 24V power system is detected.
In 24V power supply system:
• Motor defective
• Solenoid defective
• Harness short- circuit
• Replace the PCB
• Replace the short-circuited part (harness, motor, solenoid)
Error Name/Error Condition/Major Cause/Solution
No bridge unit when finisher is present
When power supply is switched on or paper is transported, finisher set is
detected but bridge unit set is not detected.
(during internal finisher connection, not detected)
• Bridge unit not attached
• Bridge unit defective
• Reset the bridge unit
• Turn the power off/on
Service Call 700-792
549

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents