Ricoh MET-C1 Field Service Manual page 442

Table of Contents

Advertisement

4. Replacement and Adjustment
• A: 4.2±2mm
• B: 2±1mm
SP No.
SP6-006-001
SP6-006-003
SP6-006-005
SP6-006-006
SP6-006-007
<Sub scan magnification adjustment>
1. Set the same test chart as the one used in the Registration adjustment in the ADF. Select a feed tray
that has A3 paper, and start copying.
2. Check whether the Sub scan magnification is within the standard range. If not, adjust it with
SP6-017-001(ADF Magnification Adj.).
Standard (Magnification tolerance)
* Same Size: Sub scan: ±5.0%
* Reduction: Sub scan: ±1.00%
* Enlargement: Sub scan: ±1.00%
440
SP Name
Side-to-Side Regist: Front
Side-to-Side Regist: Rear
Leading Edge Registration
Buckle: Duplex Rear
Rear Edge Erase
Range
±3.0mm
±5.0mm
±3.0mm
±2.5mm
±10.0mm