Heating Sleeve Unit; Replacement - Ricoh MET-C1 Field Service Manual

Table of Contents

Advertisement

Heating sleeve unit

Replacement

• The heating sleeve unit is designed with a highly soft material. Do not touch the sleeve belt unit with
your hands to prevent dents during replacement. If you have touched it and a dent has been made,
the dent will gradually become larger during operation and it can cause a fusing malfunction or
sleeve belt breakage.
• To cancel SC544-02/554-02, it is necessary to replace the fusing unit or install an intact new unit
detection fuse. If you will cancel these SCs by installing a new unit detection fuse, follow the
instruction at the end of this procedure.
• If you are replacing the heating sleeve unit for PM or any reason other than canceling these SCs,
you can discard the fuse that is packed with the new heating sleeve unit.
1.
Fusing upper cover
2.
Fusing lower cover
3.
Fusing front cover
4.
Fusing rear cover
(page
5.
Exit guide plate (left) unit [A] ( ×2)
(page
344)
(page
344)
(page
345)
346)
Fusing Unit
347

Hide quick links:

Advertisement

Table of Contents
loading