APPENDIX C: EXTERNAL MUTING AND EXTERNAL WARNING RELAYS
CONFIGURING WARNING RELAYS IN THE
RMSERVER WEB SERVER
RMServer contains two relays that can be set to trigger
when specified failure conditions occur. failsafe conditions
also can be specified which, when met, cause the relays to
be reset. These relays are connected to external devices to
trigger appropriate actions in those devices.
NOTE:
RMServer must be discovered by the
Compass control software before it can be
used for warning relays. Once RMServer has been
discovered, Compass software must be running for
warning relay functions to operate.
To enable and configure RMServer's warning relays:
1. Access RMServer's web server page as described in
"Accessing the RMServer Web Server" on page 12.
2. On the Basic Settings tab, the Relay Configuration sec-
tion displays the currently enabled failure conditions for
each relay which will trigger it to change state.
Figure 5: Relay Configuration section of the Basic Settings page of
RMServer's web server.
3. To change the conditions specified for one or both
relays, click the Setup button in the Relay Configuration
section to open the Edit Relay Setup dialog.
Figure 6: The Edit Relay setup dialog of RMServer's web server.
64
4. Click the Relay 1 or Relay 2 legend at the top of the dia-
log to select the relay you want to reconfigure.
5. There are two failure conditions that RMServer can
detect:
– A loudspeaker in the inventory goes off-line.
– A loudspeaker in the inventory signals a load fault.
6. In the Error Conditions section of the Edit Relay Setup
dialog, click the Any loudspeaker listed in the inven-
tory is detected off-line box and/or the Any loud-
speaker in the inventory signals a load fault box to
activate one or both failure conditions for the selected
relay.
7. If the Any loudspeaker in the inventory signals a load
fault box is checked, then check the Instantly (no
threshold) box to trigger the relay as soon as any load
fault is detected, or the Load faults repeat 3 times
within 1 minute box to trigger the relay only after
repeated faults are detected.
8. If desired, click the legend at the top of the dialog for the
other relay and configure its failure conditions.
9. In the Recovery Conditions section of the Edit Relay
Setup dialog, click the All loudspeakers listed in the
inventory are on-line box and/or the All loudspeakers
in the inventory are now clear from load fault box to
activate one or both conditions that signal restoration of
proper operation and trigger resetting of the selected
relay to its default state.
10. If the All loudspeaker in the inventory are now clear
from load fault box is checked, then check the Instantly
(no threshold) box to reset the relay as soon as all load
faults are cleared, or the Load faults are clear for 5
minutes box to reset the relay only after no faults have
occurred in the five minutes following clearing of the fault
condition
11. If desired, click the legend at the top of the dialog for the
other relay and configure its recovery conditions.
12. Click the Save button in the lower right corner of the dia-
log to save the changes.
13. When the Changes Saved dialog appears, click the
Restart Now button to restart RMServer. Restarting
takes about 30 seconds to complete.
NOTE:
The RMServer web server may not
return to the login page when restarting is
complete. If you do not see the login page by 30 sec-
onds after initiating restart, access the web server
again from your browser and it will appear (assuming
restarting is completed).