Neuron Id For Dx Rms Modules; Resetting The Dx Rms Module - Meyer Sound RMServer Hardware Manual

Hardware component of a compass rms remote monitoring system
Table of Contents

Advertisement

CHAPTER 6: DX RMS MODULE
Wink/Activity LED (Green)
The green Wink/Activity LED indicates the status of the
loudspeaker:
During startup, the LED blinks 10 times.
If the loudspeaker has not yet been discovered, the LED
is not lit after startup.
If the loudspeaker has been successfully discovered, the
LED flashes continuously and flashes more rapidly with
increased data activity.
When the loudspeaker is winked, either by clicking the
Wink button in Compass or by pressing the Identify but-
ton on the RMS user panel, the LED is solid green.
TIP:
The Wink function is useful for identifying
the physical loudspeaker corresponding to a
loudspeaker object in Compass.
Remote Mute Switch
The recessed Remote Mute switch on the DX RMS user
panel determines whether Compass can control muting and
soloing of the loudspeaker. The DX RMS module ships from
the factory with the switch enabled.
RMS Module
Disable: When the Remote Mute switch is set to Disable
(to the left), the loudspeaker cannot be muted and
soloed from Compass.
Enable: When the Remote Mute switch is set to Enable
(to the right), the loudspeaker can be muted and soloed
from Compass.
RMS Network Connectors
The two Weidmuller connectors transfer data to and from
the RMS network. Two connectors are provided to allow for
easy connection of multiple (daisy-chained) loudspeakers
on the network. Included with each RMS-equipped loud-
speaker are RMS cable connectors and mounting blocks for
constructing RMS cables. The RMS blocks allow the cables
to be securely attached to the RMS module with screws.
42

NEURON ID FOR DX RMS MODULES

Each DX RMS module has a unique 12-character Neuron ID
(NID) that identifies the loudspeaker on the network. The
NID should be discovered automatically by the RMServer to
which it is connected, but can be entered manually, if neces-
sary. The NID for the DX RMS module is located on the user
panel above the orange RMS Network connectors (see
Figure 11 on page 41).

RESETTING THE DX RMS MODULE

You can use the Identify button to reset the DX RMS module
when powering up the loudspeaker. This will cause the mod-
ule to be reset, and the loudspeaker to be undiscovered and
removed from the RMServer inventory.
To reset the DX RMS module:
1. Disconnect the loudspeaker's power cord.
2. Press and hold the Identify button.
3. While continuing to hold down the Identify button, recon-
nect the power cord.
4. After the Wink/Status LED blinks on and off, release the
Identify button. The DX RMS module is reset and the
loudspeaker is undiscovered and removed from the
RMServer inventory.