Test Relay Status button: Opens the Test Relay Status dia-
log.
Edit Relay Setup Dialog**
Figure 11: Relay behavior is defined in the Edit Relay Setup dialog.
Relay 1/Relay 2: Click one of these legends at the top of the
dialog to edit settings for the selected relay.
Error Conditions
This section provides check boxes for the error conditions
that will trigger a state change of the relay being edited. The
relay will change state if either of the specified conditions
occurs.
Any loudspeaker listed in the inventory is detected off-line.
Any loudspeaker listed in the inventory signals a load fault:
For this condition, one of the associated radio buttons must
be chosen.
Instantly (no threshold)
Load faults repeat 3 times within 1 minute.
Recovery Conditions
This section provides check boxes for the conditions indi-
cating restoration of normal operation that will trigger a state
change of the relay being edited. The relay will change state
if either of the specified conditions occurs.
All loudspeakers listed in the inventory are on-line
All loudspeakers listed in the inventory are now clear from
load fault: For this condition, one of the associated radio
buttons must be chosen.
Instantly (no threshold)
Load faults are clear for 5 minutes.
Click the Save button in the lower right to save the settings.
The Cancel button in the lower left exits the dialog without
saving changes. A close box for the dialog is in the upper
left corner.
Test Relay Status Dialog
Displays the current status of Relay 1 and Relay 2. The but-
ton next to each line changes the state of the indicated relay.
Click the Done button or the close box at the top left to
close the dialog and save the settings.
NOTE:
Relays remain in the state indicated in the
Test Relay Setup dialog after it is closed. They are not
reset to the value they were in when the dialog was
opened.
Advanced Settings
Figure 12: The Advanced Settings page of RMServer's web server.
NOTE:
Changes to settings in this section that are
marked with a double asterisk ( **) take effect after
RMServer has been restarted.
Firmware Update**
Current Firmware Version: Displays currently installed firm-
ware version.
Select Firmware Update File: The Choose File button opens
a file browser for navigating to and selecting firmware
update files. When a file is selected, its name is displayed
next to the button.
Update Firmware button: Clicking this button begins execu-
tion of the firmware update process using the selected file
shown above.