Star Topology with Low Voltage Systems and Junction Point
The MPS-488HP power supply is used in low-voltage sys-
tems. It is important to note that each MPS-488HP con-
sumes four RMS nodes, regardless of how many
loudspeakers are actually connected to it. The junction point
illustrates the flexibility of a free topology network.
Compass Control
Software
Mac or Windows
CAT 5E or Better Network Cable
RMS FT-10 Twisted Pair Network Cable
Belden® 8205
Composite Multiconductor Cable
Belden® 1502
Figure 7: A large system using a junction box and multiple MPS-488HPs. All junction point output ports are in parallel.
Network Switch
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
OUT 1
LINK
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
AUDIO
1 GND
2
+
3
--
EACH OUTPUT: 48VDC 96VA MAX.
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
OUT 1
LINK
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
AUDIO
1 GND
2
+
3
--
EACH OUTPUT: 48VDC 96VA MAX.
Custom RMS Hub or
Junction Point
NOTE: NEC ANSI/NFPA 70
Class 2 Wiring may be used
AC INPUT
~
100--240V
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
RMS Network
AUDIO
+
MPS-488HP = 4 RMS network nodes
--
S
Identity
+
--
Wink
48 VDC
Activity
WARNING: Risk of Fire or Electric Shock. Do not interconnect output terminations.
60 Hz 830W MAX
NOTE: NEC ANSI/NFPA 70
Class 2 Wiring may be used
AC INPUT
~
100--240V
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
RMS Network
AUDIO
+
MPS-488HP = 4 RMS network nodes
--
S
Identity
+
--
Wink
48 VDC
Activity
WARNING: Risk of Fire or Electric Shock. Do not interconnect output terminations.
60 Hz 830W MAX