RESETTING THE HP/MP RMS MODULE

You can use the Reset and Service buttons to reset the
HP/MP RMS module, which will cause the module to be
undiscovered and removed from the RMServer inventory.
To reset the HP/MP RMS module:
1. Press and hold the Service button for 10 seconds.
2. While continuing to hold down the Service button, press
and hold the Reset button for 5 seconds.
3. After releasing the Reset button, continue holding down
the Service button for 5 seconds. The HP/MP RMS mod-
ule is reset and the loudspeaker is undiscovered and
removed from the RMServer inventory. The HP/MP RMS
module's red Service LED blinks.