CHAPTER 2: INSTALLING AND CONFIGURING RMSERVER
For a complete firmware update procedure, see the section
"Updating RMServer's Firmware" on page 18.
Save and Restore Device Configuration
A device configuration file contains all of the settings from
the Basic Settings and Advanced Settings pages of the
RMServer web server page.
Save Device Configuration: Clicking the Save File button
saves the current device configuration to a file in your com-
puter's default user Downloads folder.
Upload Device Configuration**: Clicking the Upload File but-
ton opens a file browser. Navigate to and select the Device
Configuration file you wish to upload to RMServer.
Reset Device Configuration**: Clicking the Reset button
restores factory default values for RMServer.
System Operations
Restart RMServer: Clicking the Restart Now restarts
RMServer, which reloads settings. Click this button after
making changes to sections marked with a double asterisk
(**) to make the changes take effect.
Updating RMServer's Firmware
1. Login to the RMServer web server.
2. Access the Advanced Settings tab of the RMServer web
server.
3. Click the Choose File button in the Firmware Update
section to open a file browser.
4. Navigate to the firmware update file and click OK to
close the dialog.
5. Click the Update Firmware button to start the firmware
updating process.
6. When the updating process completes, restart RMServer
by clicking the Restart Now button in the dialog that
appears.
Restarting RMServer
There are four ways to restart RMServer. The front panel
Reset button is recessed, so a paper clip or similarly small
implement is required to press it.
1. Press the Reset button on the front panel once to restart
RMServer and reload the current settings.
18
2. Click the Restart Now button in the System Operations
section of the Advanced Settings tab of RMServer's web
server to restart RMServer and reload the current set-
tings.
3. Hold the Reset button on the front panel down for five
seconds while RMServer is running to restart RMServer
and restore the factory default settings.
4. Holding the Reset button on the front panel while power-
ing on RMServer will restart the unit in failsafe mode.
Continue holding the Reset button until the Fault LED
remains solid.
When the power LED stays on solid, restart is complete. In
failsafe mode, the power LED flashes slowly.
NOTE:
In the initial release of RMServer (with Com-
pass 3.0.0), if you are using Bonjour to communicate
with RMServer, the web server login page will not be
automatically displayed when restarting is complete.
However, the login page is easily accessed using any
of the regular methods.
RMServer Failsafe (Recovery) Mode
Figure 13: The failsafe mode web server page is simpler than the normal
RMServer web server page.
Failsafe mode (also called "recovery" mode) should be
invoked only in cases of serious RMServer problems, such
as a failed firmware update or an inability of RMServer to
boot properly.