Draining The Sterndrive - Mercury MerCruiser Axius 350 MAG User Manual

With emissions control
Table of Contents

Advertisement

e.
Check valve
a
3.
On models with a seawater pickup pump, remove the two blue drain plugs. If the seawater pickup pump does not have blue
drain plugs, or you are unable to access them, loosen the clamps and remove both hoses.
a -
Hose clamps
b -
Blue drain plugs
4.
Crank the engine over slightly with starter motor to purge any water trapped in the seawater pickup pump. Do not allow the
engine to start.
5.
After the cooling system has been drained completely, install the drain plugs, reconnect hoses, and tighten all hose clamps
securely.

Draining the Sterndrive

NOTE: This procedure is needed only for salty, brackish, mineral laden, or polluted water applications; and for freezing
temperatures or extended storage.
90-864197084 NOVEMBER 2008
6131
a
b
a -
Drain plug (if equipped)
Section 6 - Storage
6145
Page 129

Advertisement

Table of Contents
loading