Faults; Disturbance On The Machine Console - Wacker Neuson DPU 7060SC Operator's Manual

Table of Contents

Advertisement

Faults

8.
Faults
8.1

Disturbance on the machine console

T01052GB
Pressing the "I" (d) button does not activate the machine – LED ring (b)
does not illuminate
Cause
The vibratory plate's on-board battery
is discharged.
Button defective.
Button has no electrical contact.
LED ring has no electrical contact.
The charge control lamp (f) does not extinguish while motor is running
Cause
The on-board battery is not receiving a
charge.
Regulator or alternator is defective.
The oil control lamp (c) does not extinguish while motor is running
Cause
Engine oil level too low.
Oil pressure switch defective.
Oil pressure switch has no electrical
contact.
c
d
Remedy
Charge the battery and check the
functionality of the charge regulator if
necessary.
Replace the button with an original
replacement part.
Check connection and repair.
Check connection and repair.
Remedy
Check the relevant connections or
ask Wacker service for assistance.
Replace the regulator or ask Wacker
service for assistance.
Remedy
Fill up with engine oil.
Replace the oil pressure switch with
an original replacement part.
Check connection and repair.
30
b
f
e

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents