Forward speed too low
Reverse speed too low
No reverse motion
Loss of hydraulic oil
The charge control lamp will not extinguish and/or the buzzer will not stop buzzing
Engine does not start
T00785GB
Cause:
- To little hydraulic oil in the centre pole head.
- Air in hydraulic control.
Remedy: - Top up hydraulic oil.
- Bleed system.
Cause:
- Too much oil in centre pole head.
Remedy: - Correct oil level in accordance with mark.
Cause:
- Mechanical fault.
Remedy: - Contact Wacker service dept.
Cause:
- Leaks, hydraulic hose defective.
Remedy: - Change defective parts.
Note: Bleed system after every dismantling operation.
Cause:
- Dynamo defective.
- Control unit defective.
Remedy: - Contact Wacker service dept.
- Replace control unit (on rear of the dynamo).
Cause:
- Ignition lock defective.
- Starter defective.
- Start knop defective.
- Battery flat.
- Lack of lubricating oil.
Remedy: - Change defective parts.
- Charge battery.
- Fill up with oil and actuate valve lever at oil filter housing once.