2a. AIR CLEANER SERVICE IG2000 and IG2600
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service
the air cleaner regularly. Service more frequently when operating the generator in extremely dirty
areas.
■Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive
under certain conditions.
■Never run the generator without the air cleaner, otherwise rapid engine wear may result.
1. Loosen the cover screw and remove the left side maintenance cover.
2. Remove the air cleaner cover and remove the fine and coarse elements.
3. Wash the elements in a non-flammable or high flash point solvent and dry it thoroughly.
4. Soak the elements in clean engine oil and squeeze out the excess oil.
5. Reinstall the coarse and fine air cleaner elements and the air cleaner cover. Tighten the cover
screw securely.
6. Reinstall the maintenance cover and tighten the cover screw securely.
2b. AIR CLEANER SERVICE IG1000
The IG 1000 has a single foam element. The maintenance procedure is the same as for the other
generators