Replacing The Mains Cable; Replace The Running Roller; Reset The Safety Switch - Kärcher PW 20 Service Manual

Table of Contents

Advertisement

5.2.9 Replacing the mains cable

Remove the motor as described in Chapter 5.2.2.
Remove the mains cable from the connector on
the motor.
Loosen the hexagonal (arrow).
Remove the cable ties from the suction pipe.
Replace the mains cable and install it in reverse
order.
Install the motor as described in Chapter 5.2.2.

5.2.10Replace the running roller

1 Running roller
2 Fastening screw, running roller
Place the PW 30/1 on its back.
Loosen the fastening screw.
Replace the running roller and install it in reverse
order.

5.2.11Reset the safety switch

The safety switch is an overload protector switch and
is located underneath the protective cap (arrow). If
the brush roller is blocked, the safety switch will
switch off the appliance.
In order to restart the appliance, reset the safety
switch as follows:
Unscrew the protective cap from the casing using
a suitable flat tip screwdriver.
Press the safety switch to reset it.
Insert the protective cap and tighten it.
English 5.906-507.0 Rev. 00 (08/10)
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pw 30/1

Table of Contents