Remove Operating Panel; Replacing The Mains Cable; Replace Appliance Switch - Kärcher CV 66/2 Service Manual

Upright brush-type
Hide thumbs Also See for CV 66/2:
Table of Contents

Advertisement

5.2

Remove operating panel

The operating panel includes the appliance switch, the fuses for
the brush motor and the suction turbines and the ring core throt-
tles. The operating panel is connected to the appliance via a har-
ness, which is routed along the right handlebar.
Remove the marked screws.
Pull the cover off toward the back.
Reroute the mains cable during removal
5.3

Replacing the mains cable

If the mains cable or the mains plug are damaged, they must be
replaced.
Remove the cover (see "Disassembly of operating panel")
Carefully open cable tie (cut)
Disconnect the connectors on the supply line
Separate the protective conductor from the grounding clip.
For this, loosen the nut and pull of all the ring ferrules. The
protective conductor is installed last.
Remove the traction relief: Unscrew the locknut, hold against
traction relief
Pull the mains cable out toward the back
Route a new mains cable
Restore the protective conductor and the connections
Bundle the cables with the harness
Reinstall the cover
5.4

Replace appliance switch

A defective appliance switch must be completely replaced.
Remove the cover (see "Disassembly of operating panel")
Carefully open cable tie (cut)
Remove the connections from the switch
Press together the locking nose on the switch
Pull the switch from the holder toward the bottom
Insert new switch - observe the installation position: Pin point-
ing toward the bottom, use mark "Off" on the operating panel
as a guide
5
English

Hide quick links:

Advertisement

Table of Contents
loading