Replace The Glide Contacts Of The Suction Turbine; Replacing The Mains Cable - Kärcher NT 35/1 AP Te Service Manual

Hide thumbs Also See for NT 35/1 AP Te:
Table of Contents

Advertisement

1 Top seal ring, to the appliance hood
2 Suction turbine
3 Bottom seal ring, to the turbine holder
Replace the suction turbine.
Check the seal rings for damage.
Replace damaged seal rings.
Align the suction turbine inside the turbine holders
by means of the seal rings during installation.
8.8.1 Replace the glide contacts of the suction
turbine.
1 Glide contact (carbon brush)
2 Contact part
Unscrew the screws of the contact part.
Pull the contact part off toward the top, do not
bend the plug contact.
Remove the glide contact and replace it.
Install a new glide contact; no adjustments neces-
sary.
Always replace both glide contacts at once.
16
English 5.906-520.0 Rev. 00 (03/12)

8.9 Replacing the mains cable

Unscrew the fastening screws of the traction relief.
Disconnect the connecting cable of the mains ca-
ble on the appliance electronics and on the appli-
ance switch.
Replace the mains cable.