Wiring; Terminal Connection Diagram - Mitsubishi Electric F700 Instruction Manual

Hide thumbs Also See for F700:
Table of Contents

Advertisement

2.4 Wiring

2.4.1

Terminal connection diagram

*1. DC reactor (FR-HEL)
Source logic
Be sure to connect the DC reactor
supplied with the 01800 or more.
Main circuit terminal
When a DC reactor is connected
to the 01160 or less, remove the
Control circuit terminal
jumper across P1-P/+.
Three-phase AC
power supply
*2. To supply power to the
control circuit separately,
remove the jumper across
R1/L11 and S1/L21.
Control input signals (No voltage input allowed)
Forward
Terminal functions
rotation
vary with the input
terminal assignment
(Pr. 178 to Pr. 189)
Reverse
(Refer to the Instruction
rotation
Manual (applied))
Start self-holding selection
High speed
Multi-speed
Middle speed
selection
Low speed
Jog mode
Second function selection
*3. AU terminal
Output stop
can be used
as PTC input
Reset
terminal.
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous
power failure
Contact input common (Sink)
(Common for external power supply transistor)
24VDC power supply
Contact input common
(Common for external power supply transistor)
Frequency setting signal (Analog)
3
Frequency setting
potentiometer
1/2W1k Ω
1
*5
* 4. Terminal input
specifications can be
Auxiliary
changed by analog input
specifications switchover
input
(Pr. 73, Pr. 267). Set the
Terminal
voltage/current input
switch in the OFF
4 input
position to select voltage
(Current
input (0 to 5V/0 to 10V)
input)
and ON to select current
input (4 to 20mA).
(Refer to the
Instruction
Manual (applied))
* 5. It is recommended to use
2W1kΩ when the
frequency setting signal is
changed frequently.
CAUTION
· To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables.
· After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean.
When drilling mounting holes in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
· Set the voltage/current input switch in right position. Operation with a wrong setting may cause a fault, failure or malfunction.
Earth
Jumper
P1
MC
MCCB
R/L1
S/L2
T/L3
R1/L11
Jumper
*2
S1/L21
Earth
STF
start
STR
start
STOP
RH
RM
RL
JOG
RT
MRS
RES
*3
AU
AU
PTC
CS
SD
PC
10E(+10V)
10(+5V)
0 to 5VDC
2
2
0 to 10VDC
0 to 20mADC
5
(Analog common)
0 to ± 10VDC
(+)
1
0 to ± 5VDC
(-)
4 to 20mADC
(+)
4
0 to 5VDC
(-)
0 to 10VDC
Connector
for plug-in option
connection
Option connector 1
Resistor unit
*1
(Option)
Brake unit
(Option)
Jumper
P/+
PX
N/-
PR
CN8
*7
*7
*6
U
V
W
ON
EMC filter
ON/OFF
OFF
connector
Main circuit
Control circuit
C1
B1
A1
C2
B2
A2
RUN
SU
IPF
OL
FU
SE
PU
connector
*4
Voltage/current
input switch
4 2
ON
CA
OFF
Initial value
selected
* 4
AM
Initial
5
value
* 4
selected
TXD+
Initial
value
TXD-
selected * 4
RXD+
RXD-
SG
Terminating
resistor
VCC
*6. A CN8 connector is
provided with the
01800 or more.
*7.
Do not use PR and PX terminals.
Please do not remove the jumper
connected to terminal PR and PX.
Motor
IM
Earth
Relay output
Terminal functions
vary with the output
Relay output 1
terminal assignment
(Pr. 195, Pr. 196)
(Alarm output)
(Refer to the
Instruction Manual
(applied))
Relay output 2
Open collector output
Running
Terminal functions
vary with the output
Up to frequency
terminal assignment
(Pr. 190 to Pr. 194)
Instantaneous
(Refer to the
power failure
Instruction Manual
(applied))
Overload
Frequency detection
Open collector output common
Sink / source common
(+)
Analog current output
(0 to 20mADC)
(-)
(+)
Analog signal output
(0 to 10VDC)
(-)
RS-485 terminals
Data transmission
Data reception
GND
5V
(Permissible load
current 100mA)
Wiring
2
7