Mitsubishi Electric F700 Instruction Manual page 135

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Heatsink protrusion attachment procedure
(3) Installation of the inverter
Push the inverter heatsink portion outside the enclosure and fix the enclosure and inverter with upper and lower
installation frame.
Inside the
enclosure
Inverter
CAUTION
· Having a cooling fan, the cooling section which comes out of the enclosure can not be used in the environment of water
drops, oil, mist, dust, etc.
· Be careful not to drop screws, dust etc. into the inverter and cooling fan section.
130
Enclosure
Exhausted air
*
Installation
frame
Dimension of
Cooling
the outside of
wind
the enclosure
D1
* For the FR-F740-05470 or more, there are finger
guards behind the enclosure. Therefore, the
thickness of the panel should be less than
10mm(*1) and also do not place anything around
finger guards to avoid contact with the finger
guards.
Enclosure
140
10*
1
Inverter Type
FR-F740-04320, 04810
FR-F740-05470 to 12120
Finger guard
(Unit: mm)
D1(mm)
185
184