Parameter list
Parameter
Traverse function
592
selection
Maximum
593
amplitude amount
Amplitude
compensation
594
amount during
deceleration
Amplitude
compensation
595
amount during
acceleration
Amplitude
596
acceleration time
Amplitude
597
deceleration time
611
Refer to Pr.57 and Pr.58.
867, 869
Refer to Pr.54 to Pr.56.
872
Refer to Pr.251.
Regeneration
882
avoidance
operation selection
Regeneration
883
avoidance
operation level
Regeneration
avoidance at
884
deceleration
detection sensitivity
Regeneration
avoidance
885
compensation
frequency limit
value
Regeneration
886
avoidance voltage
gain
888
Free parameter 1
889
Free parameter 2
86
Incre
Initial
Name
ments
Value
1
0
0.1%
10%
0.1%
10%
0.1%
10%
1s
5s
1s
5s
1
0
0.1V
DC760V 300 to 800V
1
0
0.01Hz
6Hz
0.1%
100%
1
9999
1
9999
Range
Description
Traverse function invalid
0
Traverse function is valid only in the
1
external operation mode
Traverse function is valid independently
2
of operation mode
Amplitude amount during traverse
0 to 25%
operation
Compensation amount at the time of
0 to 50%
amplitude inversion
(acceleration → deceleration)
Compensation amount during
amplitude inversion operation
0 to 50%
(deceleration → acceleration)
Acceleration time during traverse
0.1 to 3600s
operation
Deceleration time during traverse
0.1 to 3600s
operation
0
Regeneration avoidance function invalid
Regeneration avoidance function is
1
always valid
Regeneration avoidance function is valid
2
only during a constant speed operation
Set the bus voltage level at which
regeneration avoidance operates.
When the bus voltage level is set to
low, overvoltage error will be less apt to
occur. However, the actual deceleration
time increases.
Set sensitivity to detect the bus voltage
0 to 5
change.
1 (Low) → 5 (High)
Set the limit value of frequency which
0 to 10Hz
rises at activation of regeneration
avoidance function.
9999
Frequency limit invalid
Adjust responsiveness at activation of
regeneration avoidance.
0 to 200%
A larger setting will improve responsiveness
to the bus voltage change. However, the
output frequency could become unstable.
Parameters you can use for your own
0 to 9999
purposes.
Used for maintenance, management, etc.
0 to 9999
by setting a unique number to each
inverter when multiple inverters are used.
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×