2.4.6

Changing the control logic

The input signals are set to source logic (SOURCE) when shipped from the factory.
To change the control logic, the jumper connector on the control circuit terminal block must be moved to the other
position.
(The output signals may be used in either the sink or source logic independently of the jumper connector position.)
CAUTION
Turn off the inverter power before switching a jumper connector.
18
Description
Select one e.g. output frequency from
monitor items.
*3
The output signal is proportional to the
magnitude of the corresponding
monitoring item.
With the PU connector, communication can be made through RS-485.
(for connection on a 1:1 basis only)
. Conforming standard : EIA-485(RS-485)
. Transmission format
: Multidrop
. Communication speed : 4800 to 38400bps
. Overall length
: 500m
With the RS-485 terminals, communication can be made through RS-485.
Conforming standard
: EIA-485(RS-485)
Transmission format
: Multidrop link
Communication speed : 300 to 38400bps
Overall length
: 500m
Output item:
Output frequency
(initial setting)
Description
Rated
Refer to
Specifications
Load impedance
Instruction
200Ω to 450Ω
Manual
Output signal 0 to
(applied)
20mADC
Output signal 0 to
10VDC
Instruction
Permissible load
current 1mA
Manual
(load impedance
(applied).
10kΩ or more)
Resolution 8 bit
Refer to
22
23