6.20. B-500-RX-230-IR IR Connections

The B-500-RX-230-IR IR ports are described below. Use the diagram for reference.
A. IR Flasher–IR output to connect to IR Flasher
B. IR Receiver–IR input to connect to IR Receiver or to output of a control system

6.21. IR Receiver

Attach an IR receiver to this port to capture IR commands in the room for pass through to sources. This port will
also send commands back to the matrix switcher for control of source selection in each zone.
12V DC(Sleeve)
GND (Sleeve)
IR Signal (Tip)

6.22. IR Flasher

Attach an IR flasher to this port for controlling a display or other equipment with commands sent from a control
system flasher output, into the matrix switcher IR INPUT TO ROOM ports and then to this port.
GND (Sleeve)
IR Signal (Tip)

6.23. Yellow Tag IR Adapter

The yellow tagged adapter included with the B-500-RX-230-IR (illustrated below) is used to plug a 3.5mm mono
mini cable into the IR Receiver port of the B-500-RX-230-IR. This is used to send IR commands to the matrix
switcher from other flasher outputs instead of an IR Receiver.
To B-500-MTRX
12V DC (Sleeve)
GND (Ring)
IR Signal (Tip)

6.24. Control System - Mono (3.5mm) IR Receiver

When using a control system which generates the signal through a mono jack, the IR RCVR PWR switch should be
in the OFF position.
A
FIGURE 7:
FIGURE 8:
FIGURE 9:
To IR Control System
Connecting Block
FIGURE 10:
GND (Sleeve)
1
IR Signal (Tip)
FIGURE 11:
14
B
or
GND (Sleeve)
IR Signal (Tip)