How To Learn Edid To All Inputs; Viewing Input Edid Status; Advanced Setup Using The Configuration Utility; Ir Source Routing - Binary B-500-MTRX-230-8x16 Installation Manual

Table of Contents

Advertisement

7.11. How to Learn EDID to All Inputs

Example: Input=All EDID Learned from Output 4
1. Press LEARN
2. Press OUTPUT
3. Press Number Key (1-8) to select the Output the EDID is learned from.
Use 10+ to select Outputs through 10-16
4. Press ENTER

7.12. Viewing Input EDID Status

If there is a question about the EDID set for an input, the status of that input's EDID can be reviewed using the
included IR remote and watching the matrix switcher front panel display.
Example: View the EDID for Input 3.
1. Press STATUS
2. Press INPUT
3. Press Number Key (1-8)to select the desired
Input. Use 10+ to select Outputs through 10-16
4. Press ENTER
Notes about EDID Status
If the EDID was learned from an output, the exact EDID specifications will not be shown, but the output
number will be identified. Review the specifications of the display attached to the output to determine its
compatible resolutions.
If the second digit (the Input being queried) has a dot after it, then the first digit is the EDID number from the
Embedded EDID table.
If the second digit (the Input being queried) does not have a dot after it, the first digit is the output the EDID
was learned from (step 4 from example above).

8. ADVANCED SETUP USING THE CONFIGURATION UTILITY

There are several setup options available that can only be modified using the matrix switcher Configuration Utility.
These items are defaulted to the most common settings that should work in most installations.
The Configuration Utility and manual are available for download on the Support Tab of the B-500-MTRX-230
product page. Download and run the Utility to gain access to these settings connecting to the matrix and clicking
Other Settings.

8.1. IR Source Routing

Default Setting:
The IR Source Routing feature allows discrete control of the source selected from any connected HDBaseT
output using an IR receiver plugged into the B-500-RX-230-IR. This setting is only relevant when using in-room
IR remotes to control sources connected to the matrix switcher. When set to Yes, the matrix will route commands
from the HDBaseT Receiver to the IR Output to Source port that matches the source input number currently
selected on that output.
When set to No, commands will be sent only out of the IR Output to Source port that matches the HDBaseT
Receiver number from which it originated.
Display Readout (Example)
EDID 5 Assigned from
Embedded EDID Table
 
 
 0..
0 0..
Yes
20
Display Readout (Example)
L._. 
L._. 
04 .  .
 
(success)
(fail)
FF FF
EDID Learned from
Output 4
 
 
 0..
0.4. 0..

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-500-mtrx-230-16x16

Table of Contents