Accessing The Installer Menu - Bentel Security KYO 320 Installation Manual

Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Enable Partitions in A, B, C or D Mode
Keys 1 to 8 will allow you to enable/disable the Parti-
tions and set up A, B, C and D operating Mode.
The first eight positions on the bottom line of the display
(1 through 8) indicate the Partition status, as follows:
û— the element concerned is enabled on, or assigned
to the respective Partition;
A— Away mode (ALL Zones ON);
S— Stay mode ("Internal" Zones OFF);
I— Instant mode (Stay mode with zero delay);
D— Disarm;
N— No change to the current status (None).
In order to allow you to program the 32 Partitions of the
KYO 320, from the keypad, this programming section
has been divided into 4 Partition groups:
1st group — Partitions 1 to 8;
2nd group — Partitions 9 to 16;
3rd group — Partitions 17 to 24;
4th group — Partitions 25 to 32.
Keys 1 to 8 correspond respectively to the first 8 Parti-
tions. For Partitions 9 to 16 — key 1 corresponds to Par-
tition 9, key 2 to Partition 10 and so forth to key 8 which
corresponds to Partition 16. The same applies to Parti-
tions 17 to 24 and 25 to 32 (see Table) :
KEYS
1
1-8
1
Keys to use for
9-16
9
Partition
17-24
17
groups...
25-32
25
DISPLAY
1
In Partition group 1 to 8, key 2 and position 2 on the di-
splay correspond to Partition 2.
KEYS
1
1-8
1
Keys to use for
9-16
9
Partition
17-24
17
groups...
25-32
25
DISPLAY
1
In Partition group 9 to 16, key 2 and position 2 on the di-
splay correspond to Partition 10.
Time
Partition status:
=Disarmed
D
=armed in Away mode
A
=armed in Stay mode
S
=armed in Instant mode
I
6
2
3
4
5
6
7
2
3
4
5
6
7
10
11
12
13
14
15
18
19
20
21
22
23
26
27
28
29
30
31
2
3
4
5
6
7
2
3
4
5
6
7
2
3
4
5
6
7
10
11
12
13
14
15
18
19
20
21
22
23
26
27
28
29
30
31
2
3
4
5
6
7
Date
KEYS
Keys to use for
Partition
groups...
DISPLAY
Press C or D to view the required section.

Accessing the Installer menu

When the system starts, on the display keypad is possi-
ble to select the programming languages:
1:<ITA>
3: ESP
1. Enter the number which corresponds to language
and then press ENTER.
2. only if the system has a number of PREMIUM LCD
and CLASSIKA LCD keypads greater than 5, the upda-
te strings fase follows.
8
Access to the programming phase will be denied when
8
the Partitions are Armed or the Partition Patrol Times
16
are Active.
24
NOTE: If the system is already up and working, access
requires the consent of all the system users.
32
To access the Installer menu from standby status:
8
1. Enter an Active Installer Code PIN.
11.50 27/08/2002
pin:
****XX
8
8
At default, only Installer Code no. 200 (PIN 0200) has
16
Active status for KYO 320.
24
2. Press ENTER
32
8
INSTALLER MENU
Event logger
Once you have accessed the Installer menu, the Con-
trol panel will:
Ø set all the keypads to standby status, except the one
you are using (the label of the keypad concerned will
be shown on all the system keypads);
Ø clear all the Alarm memories;
Ø set all the Outputs to standby;
Ø lock the event evaluation;
Ø interrupt ongoing calls (if necessary), and put the
Call queue on hold.
+
Teleservice calls will NOT be interrupted.
1
2
3
4
1-8
1
2
3
4
9-16
9
10
11
12
17-24
17
18
19
20
25-32
25
26
27
28
1
2
3
4
2:ENG
4:FRA
5
6
7
8
5
6
7
8
13
14
15
16
21
22
23
24
29
30
31
32
5
6
7
8
KYO320

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents