Zone Status; Zone Test - Bentel Security KYO 320 Installation Manual

Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

+
This function is provided by the optional K3-PRT2
Printer Interface.
The Event logger
The Event logger is set up as follows:
Ø the Event number (Ev.) is shown on the left side of
the first line;
Ø the Event details (TYPE, IDENT., USER, USER ID,
TIME) are shown on the second line.
Using the Event Logger:
Ø Use A and B to scroll the Events.
Ø Press D to view the Event details (see above).
Ø Press ESC to step back to the Event Logger menu.
+
The display will show the details of each Event. For exam-
ple, Tamper Events show the TYPE and TIME only.

Zone status

This option will allow you to view the status of the zones
(Standby, Alarm, Tamper, Short-circuit or Bypassed,
and also the Zone voltage level). This option is impor-
tant during installation and placement tests.
Double-balance zones can signal Short-circuit,
Standby, Alarm or Tamper status.
Balance zones can signal Short-circuit, Standby or
Alarm status. NC and NO zones can signal Standby or
Alarm only. If a zone is about to change status, the di-
splay may show the intermediate status before showing
the final status.
+
For example, if a Double Balance zone is changing
from Standby to Tamper, the Zone status option
may indicate Alarm Status for several seconds be-
fore finally showing Tamper status.
To view the Zone status, work carefully through the fol-
lowing steps.
From the Installer menu:
INSTALLER MENU
Event logger
1. Using A or B, select the Zone status option, then
press ENTER.
zone n.
001
South entrance
2.Using A or B, scroll the zones or enter the zone ID
number (three digits required).
NOTE: Wrong entries will be signalled by an audible er-
ror signal.
zone n.
002
Staircase Window
3.Press ENTER to view the status.
8
Staircase Window
STBY UNBYPASSED
4. Press ENTER again to view the Zone Resistance (in
ohm, see the example below).
Staircase Window
4265 ohm
5. Press ESC to go back to the Installer menu.
On the contrary, if you press ENTER it is possible to
check, one at time, the zone with "Vibration" attribute (if
in programming fase the same zone has been program-
med with "Vibration" attribute and has been program-
med the sensitivity and the pulse number):
Zone n.
001
Vibrat. Test 001

Zone test

This option will allow you to test all the partition zones
without generating alarms. The Test event will be recor-
ded in the event logger as: <Alarm - Zone under test>.
The following events may also be recorded in the log-
ger: keypad buzzer or activation of Output 1; or keypad
buzzer+activation of Output 1.
From the Installer menu:
INSTALLER MENU
Event logger
1.Using A or B, select the Zone test option, then press
ENTER.
Zone test
Logger only
2.Using A or B, select Test mode, then press ENTER.
Partition
001
Test
ON
3.Using A or B, select the Partition the zones belong to.
Partition
002
Test
ON
4.Using ON or OFF respectively, to activate/stop the
test for the partition concerned. Press ENTER to run the
test.
Test running...
NOTE: The Zone status (Activated or Restored)
will be recorded in the Event Logger.
5.Press ESC to go back to the Installer menu
KYO320