CipherLab 1800 series Reference Manual page 156

Handheld rfid reader
Hide thumbs Also See for 1800 series:
Table of Contents

Advertisement

1800 Series Handheld RFID Reader
Example1 (Prefix of the Counter Section):
Command
#@dat_pfx=0,23
Response (s)
OK
#
39.
2012-04-12 Fri 04:00 55.95 3000343033313030313230303030422112
Command
#@dat_pfx=0,23436f756e74657223
Response (s)
OK
#Counter
40.
Command
#@dat_pfx=1,@
Response (s)
OK
@
41.
2012-04-12 Fri 04:00 55.95 30003430333130303132303030304221
Example2 (Suffix of the EPC Data Section):
Command
#@dat_pfxidx=6
Response (s)
OK
Command
#@dat_pfx=0,454e440d
Response (s)
OK
42.
2012-04-12 Fri 04:00 55.95 30003430333130303132303030304221END
144
Reference Manual
→ set prefix to 0x23 ('#')
→ set prefix to
0x23
(respective characters are: #
the length exceeds 8 bytes so the last code 0x23 ('#) will
be truncated.
2012-04-12 Fri 04:00 55.95 30003430333130303132303030304221
→ set prefix to '@'
→ setting the prefix/suffix buffer index to 6 means to
configure the suffix of the EPC data section
→ set the suffix to 0x45
characters are: E, N, D, \r)
0x43
0x6f
0x75
0x6e
0x74
0x65
C
o
u
n
t
0x4e
0x44
0x0d (respective
0x72
0x23
e
r
#);

Advertisement

Table of Contents
loading

Table of Contents