ISDN Interfaces
Call Monitor Output for ISDN
The hardware connections and communication parameters for the ISDN monitor port are shown in
Figure
5-30. Once this connection is setup and established, call monitoring data continues to be
sent (on the fly) as PRI and BRI calls are originated or received.
Two sample printouts from the RPTU monitor are provided.
start-up and synchronization sequences that occur at connection and power on.
typical ISDN PRI outgoing call setup and release sequences. BRI monitor data is similar to PRI
monitor data.
The communication parameters for all call-monitor jacks are 9600 bps, 7, 1, even.
The RPTU, RBSU and RBUU ISDN interface PCBs each have a call-monitor jack. The pin
Note
numbering and communication parameters are the same for each call-monitor jack. The
call-monitor jack on each PCB provides data only for the circuits of the PCB on which it
appears.
Figure 5-30
Call-monitor Jack for the RPTU, RBSU, and RBUU
Call Monitor Output for ISDN
See the following figures for examples of Call Monitor Output printouts.
5-34
Strata PRI or BRI PCB Monitor Jack
Call-monitor jack
Dealer-supplied 6-wire
telephone modular cord
(cross-pinned)
RD
1
TD
2
DSR
3
DTR
4
DCD
5
SG
6
4696
Figure 5-30
PC with communication
software - such as ProComm™
PC DB9 or
DB25 Com port
Toshiba PPTC9 or
PPTC25F
Call-monitor jack (RJ12)
pin numbering
shows typical ISDN PRI
Figure 5-31
shows
Strata CTX I&M
10/02