Toshiba STRATA CTX100 Installation And Maintenance Manual page 207

Digital business telephone systems
Hide thumbs Also See for STRATA CTX100:
Table of Contents

Advertisement

A cord of up to 10 meters connects the ISDN BRI RJ45 wall jack to the desktop TE-1 or TA RJ45
jack. Bellcore recommends that all TE-1 and TA devices be attached with the same standard cord
to ensure compatibility.
Figure 5-13
Modular ISDN Data Cable
The standard pinouts for ISDN jacks is the TIA-568A or TIA-568B jack as listed in
variants A and B to the TIA specification are electrically the same, only the wire colors are
different. However, you should only use one type TIA jack in a customer installation because
mixing the two may cause certain wire pairs to be swapped which would result in line faults.
Table 5-7
TIA-568B (RJ45) Jack – ISDN Standard Interface Modular Connector Pinout (RBSU-NT mode)
Pin
1
Green
2
Green/White
3
Orange/White
4
Blue/White
5
Blue
6
Orange
7
Brown
8
Brown/White
Notes
Pins are numbered left to right when looking into the jack cavity with the locking tab down.
TIA-568A swaps pair two with pair three, changing only the color of the wires on the pins.
Electrical performance is the same.
Strata CTX I&M
10/02
3039
Four-pair Wire
Color
Name
T2
Power 3 (not used on RBSU/RBSS)
R2
Power 3 (not used on RBSU/RBSS)
R3
RX+
R1
TX+
T1
TX-
T3
RX-
T4
- Power 2 (not used on RBSU/RBSS)
R4
+ Power 2 (not used on RBSU/RBSS)
Locking Tab
RJ-45
Eight-pole Plug
Function
ISDN Interfaces
RBSU/RBSS Interface Units
Table
5-7. The
5-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx670

Table of Contents