Electric Wiring - Vivax ACP-18CC50GEI User Manual

Table of Contents

Advertisement

● Warning: Befone obtaining access to terminals, all supply circuits must be disconnected.
● Electric wiring
1、All field supplied parts and meterials must conform to local laws and regulations.
2、For electric wiring,refer to WIRING DIAGRAM attached to the unit body.
3、All wiring must be performed by a skilled technician.
4、A circuit breaker capable of shutting down power supply to the entire system and which have at
least 3 mm contact seperation in each jole must be install in the fixed wiring.
5、Earth properly.
6、Wiring must conform to national laws and regulations.
7、The fixed wiring must be installed with a protector with no more that 30 mA leakage current.
8、If the supply cord is damaged, it must be replaced by the manufactory or its service agents or a
similarty qualified person in order to avoid a hazard.
● Wiring of unit and the controller
1、Wiring of the indoor unit.
2、 Remove the control box lid(1),pull the wires inside through rubber bush and wiring according to the
WIRING DIAGRAM , then tighten it with clamp.
3、Wiring of the controller
4、Remove the control box lid(2),pull wires inside through rubber bush and connect to the controller.
5、Wrap the wire with sealing pad(12).
6、After wiring,tighten it with clamp and fix the control box lid(1),(2).
7、Heating and cooling:connect the rubber wire (5-cords) to the power supply terminal board in
properly.
8、Cooling:connect the rubber wire (3-cords) to the power supply termiral board properly.