Installation Of Outdoor Unit; Electric Wiring - Vivax GWC09TB-S3DNA1B Owner's Manual

Table of Contents

Advertisement

Installation of Outdoor Unit

Remove the handle on the right side plate of outdoor unit.
1.
2.
Take off wire clamp. Connect and fix the power connection cord to the terminal board.
Wiring should fit that of indoor unit.
3.
Fix the power connection cord with wire clamp.
Confirm if the wire has been fixed properly.
4.
Reinstall the handle
5.
NOTE:
Incorrect wiring may cause malfunction
of spare part.
After the wire has been fixed, ensure
there is free space between the connection and fixing places on the lead wire.
1. Connect charging hose of manifold valve to charge end of low pressure
valve (both high/low pressure valves must be tightly shut).
2. Connect joint of charging hose to vacuum pump.
3. Fully open the handle of Lo manifold valve.
4. Open the vacuum pump for vacuumization. At the beginning,
slightly loosen joint nut of low pressure valve to check
if there is air coming inside. (If noise of vacuum pump
has been changed, the reading of multimeter is 0) Then
tighten the nut.
5. Keep vacuuming for more than 15mins and make sure the reading of multimeter is
5
-1.0
10 pa (-76cmHg).
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of low pressure valve.
8. Tighten lid of low pressure valve. (As shown in Fig.10)
Outdoor
During heating operation, the
water should be drained out reliably through the drain hose.
Install the outdoor drain connector in a Φ25 hole or
the
base plate and attach the drain hose to the
so
that the waste water formed in the outdoor unit can be
drained ou t
.The hole diameter 25 or 42 must be plugged.
Whether to plug other holes will be determined by the dealers
to actual conditions.
The 09 12K TB UNIT drainage hole consists of two Φ42 and
two kidney holes (see the fig.11). The drain plug consists of one
Φ
42 and two kidney plugs.
(The figures in this manual may be different with the material
objects, please refer to the material objects for reference)

Electric Wiring

Air Purging and Leakage Test
Condensate
Drainage (only for Heat pump unit)
condensate
and defrosting
28
Handle
-76cmHg
Low-pressure
valve (Lo) Open
Liquid valve
Gas valve
09K TA 18K 24K 28K UNIT:
Φ42 hole on
connector
09 12K TB UNIT:
.
Hose (available commercially,
inner dia. 16mm)
yellow-
brown
green
Indoor unit connection
Manometer
High-pressure
valve (Hi) closed
Charging hose
Vacuum
pump
Fig.10
Drain-water hole
Bottom frame
Didney holes
Drain-water hole
Bottom frame
Drain plug
Drain connecter
Didney holes
Fig.11