OUTDOOR UNIT WIRING 
 
 
 
A  main  switch  or  other  means  of  disconnection,  having  a  contact  separation  in  all
 
poles, must be incorporated in the fixed wiring in accordance with relevant local laws
 
and regulations. Switch off the power supply before making any connections. Use only
 
copper  wires.  Never  squeeze  bundled  cables  and  make  sure  they  do  not  come  in
 
contact with the piping and sharp edges. Make sure no external pressure is applied to 
 
the  terminal  connections.  All  field  wiring  and  components  must  be  installed  by  a
 
licensed electrician and must comply with relevant local laws and regulations. 
 
 
The field wiring must be carried out in accordance with the wiring diagram supplied 
 
with the unit and the instructions given below. 
 
Be sure to use a dedicated power supply. Never use a power supply shared by another
 
appliance. 
 
Be sure to establish a ground. Do not ground the unit to a utility pipe, surge protector,
 
or telephone ground. Incomplete grounding may cause electrical shock. 
 
 
Be sure to install a ground fault circuit interrupter (30 mA). Failure to do so may cause
 
electrical shock. Be sure to install the required fuses or circuit breakers. 
 
 
 
Precautions on electrical wiring work 
 
Fix cables so that cables do not make contact with the pipes (especially on the high 
pressure side). 
Secure the electrical wiring with cable ties as shown in figure so that it does not 
come in contact with the piping, particularly on the high‐pressure side. 
Make sure no external pressure is applied to the terminal connectors.
When installing the ground fault circuit interrupter make sure that it is compatible 
with  the  inverter  (resistant  to  high  frequency  electrical  noise)  to  avoid 
unnecessary opening of the ground fault circuit interrupter. 
 
 
 
The  ground  fault  circuit  interrupter  must  be  a  high‐  speed  type  breaker  of  30  mA 
 
(<0.1s) 
 
 
This unit is equipped with an inverter. Installing a phase advancing capacitor not 
only  will  reduce  the  power  factor  improvement  effect,  but  also  may  cause 
abnormal heating of the capacitor due to high‐frequency waves. Never install a 
phase advancing capacitor as it could lead to an accident.  
 WARNING 
 
 NOTE 
23 
-