1、The power cable used in the unit is copper cable, the working temperature should not exceed the specified value.
2、If the power cable is longer than 15 meters, please enlarge the cross section of power cableadequately, in order to
avoid the accident due to overload.
● Requirement for ground
☆ Air conditioner is the I class electric appliance, thus please do conduct reliable grounding measure.
☆ The yellow-green two-color wiring of air conditioner is grounding wire and can not be used for
other purposes. It cannot be cut off and be fixed by screw, otherwise it would cause electric shock.
☆ The user must offer the reliable grounding terminal. Please don't connect the grounding wire
to the following places:
① Water pipe;
② Gas pipe;
③ Blowing pipe;
④ Other places that professional personnel consider them unreliable.
The power cable, communication wire connection between indoor and outdoor
Power supply
Capacity of
switch(A)
220¬230V IN¬
220¬230V IN¬
220¬230V IN¬
Min. cross
air
sectional area
of ground
line(mm2)
20
2.5
20
2.5
25
.0
4
Min. cross
sectional area of
power cable
(mm2)
2.5
2.5
.0
4
49