Caution:
1. The communication distance between the main board and the wire controller can be as far as
20m (The standard distance is 8m).
2.The wire controller shall not be installed in a place where there is water drop or large amount of
water vapor.
Caution:
Before installing the electrical equipment, please pay attention to the following
matters which have been specially pointed out by our designers:
(1) Check to see if the power supply used conforms to the rated power supply specified on the
nameplate.
(2)
The capacity of the power supply must be large enough. The section area of fitting line in
the room shall be larger than 2.5mm2.
(3) The lines must be installed by professional personnel.
An electricity leakage protection switch and an air switch with gap between electrode heads larger
than 3 mm shall be installed in the fixed line.
1、 Connection of single wire
(2) Use wire stripper to strip the insulation layer (25mm long) from the end of the single wire.
(3) Remove the screw at the terminal board of the air-conditioning unit.
(4) User pliers to bend the end of the single wire so that a loop matching the screw size is
formed.
(5) Put the screw through the loop of the single wire and fix the loop at the terminal board.
2、Connection of multiple twisted wires
(1) Use wire stripper to strip the insulation layer (10mm long) from the end of the multiple
twisted wires.
(2) Remove the screw at the terminal board of the air-conditioning unit.
(3) Use crimping pliers to connect a terminal (matching the size of the screw) at the end of the
multiple twisted wires.
(4)
Put the screw through the terminal of the multiple twisted wires and fix the terminal at the
No.
Name
1
Wall Surface
2
Bottom Plate of Wire Controller
3
Screw M4X10
4
Panel of Wire Controller
46