Support Angle Fitting; Attaching Air Restrictors - Valor 534 XAN Installation And Owner's Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

7.6 Support Angle Fitting

See figure 26
The distance from the wall angles to the front face of the heater case is
3
adjustable between
/
" (10mm) and 1
8
of wall finish material thickness (e.g. tile etc).
1. Fit the top angle support to the case top with three screws.
2. Fit the two side angle supports with two screws each. Fit the screws
from inside the heater case.

7.7 Attaching Air Restrictors

No restrictors are required for appliances, which only have a
horizontal vent, run. If installing an appliance, which has rear vent
outlet connection and no vertical vent pipe rise, ignore this stage.
There are three types of restrictor supplied with each #534 engine unit.
They are identified in figure 27.
Type "A" is for horizontal vent termination.
Types "B" & "C" are for through-the-roof termination.
The restrictors cover part of the openings in the firebox rear wall ports –
See figure 28.
The correct restrictors to be fitted for each type of installation are
shown in the table below.
Figure 28 Restrictor locations
To fit type "A" restrictors remove the center screws
from the rear ports and fit the restrictors using these
screws. To set the restrictors at maximum port opening,
slacken the bottom screws in the ports, slide the
restrictors down as far as possible and tighten the screws
over the restrictors.
To set the restrictors at minimum port opening, slide the
restrictors up as far as possible and tighten the screws.
To fit types "B" or "C" restrictors remove the top and
bottom screws from the rear ports and fit the restrictors using these screws.
3
/
" (30mm) to allow for a range
16
Figure 27 Restrictor identification
Vent
terminal
Horizontal
through
wall with
vertical rise
Vertical
through roof
21
Figure 26 Support angles
Appliance
Vertical
vent outlet
vent
pipe
run
Top
Less than 3ft
(91cm)
From 3ft
(91cm) to 6ft
(183cm)
Rear
Less than 3ft
6" (107cm)
From 3ft 6"
(107cm) to
6ft (183cm)
Top or rear
Less than
20ft (6.1m)
From 20ft
(6.1m) to
40ft (12.2m)
Use
Port
restrictor
opening
type
set at
A
Maximum
A
Minimum
A
Maximum
A
Minimum
B
Not
applicable
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

534xap

Table of Contents