4.1 Framing

The framing dimensions are shown
in figure 4.
A non-combustible hearth is not
necessary in front of this
appliance.
Note that the unit is installed at
the framing stage and fixed to
framing using support angles
(see figures 27 and 31). Wall
finish is then installed over the
support angles up to the black
frame on the unit
NOTE: If using a 612DKA
or a 613CCB front, refer to
the kit's instruction manual
for framing dimensions.

4.2 Rear Vent Connection. Flat on Wall

See figure 5.
Requires standard vent kit #551DVK only.
The horizontal vent run cannot be extended by the use of any vent accessory pipes.

4.3 Rear Vent Connection. Flat on Wall with Snorkel Termination

See figure 6.
For use on horizontal installations where the outsides ground level is too close to the standard terminal. Adapter #817VAK, a
pipe length and snorkel termination will be required (see vent options section of this manual).
Figure 5 Rear vent. Flat on wall

4. LOCATION

Figure 4 Framing
9
Figure 6 Rear vent. Flat on wall with Snorkel
This is the framing
width.
Wall finish to
32 3/16" wide.