Direct vent gas fireplace heater
Table of Contents

Advertisement

3.1 Approvals & codes
These appliances are certified by C.S.A. for use in Canada and the USA. These appliances are for installation directly venting
through an outside wall or through the roof.
Model 534XAN is for use with natural gas.
Model 534XAP is for use with propane. It can be converted for use with natural gas with kit #607NGK.
These appliances comply with CGA P.4.1, Testing method for measuring annual fireplace efficiencies.
The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code, ANSI
Z223.1or the Canadian installation code CAN/CGA-149. Only qualified licensed or trained personnel should install these
appliances.
These appliances, when installed, must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

3.2 Ratings

Model
Gas
Altitude (Ft)
Input Max. (Btu/h)
Input Min (Btu/h)
Manifold pressure (in.w.c.)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
1
Tested to CAN/CGA - 2.17 Gas fired appliances for use at high altitudes. In the USA, installations may require deration over
2000ft - Check local codes.

3.3 Wall Thickness

The vent system (when horizontally terminated) is approved to pass through combustible wall construction of up to 14"
(36cm) thick.
A non-combustible wall can be any thickness up to the maximum horizontal run of vent pipe allowed for the particular
installation – See section 4.

3. GENERAL

534XAN
534XAP
Natural
Propane
1
0-4500
24,000
24,000
6,500
13,000
3.8-4.2
9.3-9.7
5.0
11.0
10.5
14.0
8