5. During the initial operation
of a brand new appliance (or
after it has not been used for
some time), a slight amount
of fumes and smell may be
noticed for a short while. This
can be remedied by running
the heater immediately at
maximum output and ensur-
ing adequate room ventila-
tion.
6. If the burner makes an un-
usual noise or if the flame
lifts off, it is likely that the
regulator is faulty and it is es-
sential to have it checked.
7. Items sensitive to heat
(e.g. spray cans) must not be
stored in the installation area,
since excess temperatures
may under certain circum-
stances be incurred there.
8. Only pressure control
equipment that complies
with EN 12864 (in vehicles)
with a fixed delivery pressure
of 30 mbar (or 50 mbar in
older systems) must be used
for the gas system. The flow
rate of the pressure control
device must correspond to at
least the maximum con-
sumption of all devices in-
stalled by the system manu-
facturer.
For vehicles we recommend
the Truma caravan regulator
and the Duomatic Plus gas
pressure regulator kit for the
two-bottle system. Truma
regulators have been special-
ly developed for the harsh
stress conditions in caravans
and vehicles. As well as a
safety valve that provides
protection against overpres-
sure, they also have a pres-
sure gauge that can be used
to check the tightness of the
gas system. The pressure
control equipment should be
operated with a de-icing sys-
tem (Eis-Ex) at temperatures
around 0°C and below.
Controller connecting hoses
that meet national regulations
must always be used in the
respective country for which
the equipment is destined.
These hoses must be
checked regularly for brittle-
ness. Winter-proof special
hoses must always be used if
the equipment is operated
during the winter.

Technical data

determined in accordance
with EN 624 or Truma test
conditions
Type of gas: Liquid gas
(propane/butane)
Operating pressure:
30 mbar (28 mbar for butane/
37 mbar for propane) or
50 mbar (see manufacturer's
plate)
Rated thermal output
S 3002 (P): 3400 W
S 5002: 5500 W
Gas consumption
S 3002 (P): 30 - 280 g/h
S 5002: 60 - 480 g/h
Operating voltage:
1.5 V
Power consumption:
50 mA (ignition)
0.01 mA (monitoring)
Weight
S 3002 (P): 9,8 kg (without fan)
S 5002: 17,5 kg (without fan)
Declaration of conformity:
The Trumatic S has been ap-
proved by the DVGW and
complies with the EC guide-
lines (90/396/EWG) for gas
appliances as well as with
the associated EC guidelines.
The product ID No. for EU
countries is:
S 3002 (P): CE-0085AP0325
S 5002: CE-0085AP0326
EEC Type Approval:
e1 022603
The right to effect technical
modifications is reserved!
Manufacturer's
terms of warranty
1. Case of warranty
The manufacturer grants a
warranty for malfunctions in
the appliance which are
based on material or produc-
tion faults. In addition to this,
the statutory warranty claims
against the seller remain
valid.
A claim under warranty shall
not pertain
- for parts subject to wear
and in cases of natural wear
and tear,
- as a result of not original
Truma parts being used in
the appliance and as a re-
sult of unsuitable gas pres-
sure regulators being used,
- as a consequence of failure
to respect Truma instruc-
tions for installation and
use,
- as a consequence of im-
proper handling,
- as a consequence of im-
proper transport packing,
not arranged by Truma.
2. Scope of warranty
The warranty is valid for mal-
functions as stated under
item 1, which occur within
24 months after conclusion
of the purchase agreement
between the seller and the fi-
nal consumer. The manufac-
turers will make good such
defects by subsequent fulfil-
ment, i.e. at their discretion
either by repair or replace-
ment. In the event of manu-
facturers providing service
under warranty, the term of
the warranty shall not re-
commence anew with regard
to the repaired or replaced
parts; rather, the old warranty
period shall continue to run.
More extensive claims, in
particular claims for compen-
satory damages by pur-
chasers or third parties, shall
be excluded. This does not
affect the rules of the product
liability law.
The manufacturer shall bear
the cost of employing the
Truma customer service for
the removal of a malfunction
under warranty - in particular
transportation costs, travel-
ling expenses, job and mater-
ial costs, as long as the ser-
vice is carried out in Ger-
many. Customer service car-
ried out abroad is not cov-
ered by the warranty.
Additional costs based on
complicated removal and in-
stallation conditions of the
appliance (e.g. removal of
furniture or parts of the vehi-
cle body) do not come under
warranty.
3. Raising the case of
warranty
The manufacturer's address
is: Truma Gerätetechnik
GmbH & Co. KG, Wernher-
von-Braun Strasse 12,
D-85640 Putzbrunn. In Ger-
many, in the event of faults
the Truma Service Centre
should in principle be con-
tacted; abroad, the individual
service partners are available
(see address list). Any com-
plaints are to be described in
detail. In addition, the proper-
ly completed guarantee cer-
tificate is to be presented, or
the factory number of the
unit and the date of purchase
given.
In order for the manufactur-
ers to be able to determine
whether an incident subject
to guarantee has occurred,
the end user must, at his own
risk, bring the device to the
manufacturers or send it to
them. If there is damage to
heaters (heat exchangers),
the gas pressure regulator
must also be sent back to the
factory.
In instances of the device be-
ing sent to the works, dis-
patch is to be effected by
freight transport. In cases un-
der guarantee, the works
shall bear the transport costs
or the costs of delivery and
return. If the damage is
deemed not to be a warranty
case, the manufacturer shall
notify the customer and shall
specify repair costs which
shall not be borne by the
manufacturer; in this case,
the customer shall also bear
the shipping costs.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trumatic s 5002

Table of Contents