Room Thermostat; Operating Instructions; Switching Off - Truma Trumatic S 3002 P Operating Instructions Manual

Hide thumbs Also See for Trumatic S 3002 P:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
Operating
instructions
Always observe the oper-
ating instructions and
„Important operating
notes" prior to starting!
The vehicle owner is respon-
sible for correct operation of
the appliance.
The installer or vehicle owner
must affix the yellow sticker
with warning information en-
closed with the appliance to
a place in the vehicle where it
is clearly visible to all users
(e.g. on the wardrobe door)!
Ask Truma to send you a
sticker if necessary.
a = Control knob
(Thermostat)
b = Integrated control switch
for the Trumavent fan TEB
c = Pressure igniter (model
Trumatic S 3002 P)
d = Automatic ignition device
with battery compartment
(model Trumatic S 3002/
S 5002)
e = Remote ignition display
(special accessory)
f = Window to check flame
g = Thermostat sensor
h = Name plate
(remove cover)
In the case of left-handed in-
stallation, the parts are
arranged on the other side.
Taking into
operation with the
piezo ignitor
(S 3002 P only)
1. Turn on gas cylinder and
open quick-acting valve in
the gas supply line.
.
.
.
.
.
.
.
.
.
2. Turn control knob (a) to
thermostat setting 1 - 10 and
press it down as far as the
stop. At the same time keep
operating the piezo ignitor
rapidly until the flame ignites.
3. Keep the control knob
pressed down for a further
10 seconds to allow the safe-
ty pilot to operate.
4. Observe through the in-
spection window for a further
10 seconds so as to check
that the flame has not been
extinguished due to air in the
line (caused by a change of
gas cylinder).
Always wait at least
2 minutes before at-
tempting to re-ignite,
otherwise risk of blowb-
ack (misfiring)! This also ap-
plies if a working heater goes
out and has to be re-lit.
If air has got into the gas line,
it may take up to two minutes
before gas is available for
combustion. During this peri-
od, the operating handle
should be kept pressed down
and the pressure igniter con-
stantly actuated until the
flame appears.
5. To ensure even and rapid
warm air distribution as well
as lower surface tempera-
tures on the heating unit, we
recommend that you operate
the heater with a running
Trumavent warm air system.
The Trumatic S 3002 P
heating system (with
pressure igniter) is designed
in such a way that the subse-
quent installation of an auto-
matic igniter can be carried
out with no problem at all
(ZAS additional fitting set,
Art. No. 30010-29200).
Taking into
operation with the
automatic ignitor
(S 3002/S 5002)
Before using the heater for
the first time, ensure that a
battery has been inserted
(see „Changing the Batteries")!
1. Turn on gas cylinder and
open quick-acting valve in
a
the gas supply line.
.
.
.
.
.
.
2. Turn control knob (a) to
thermostat setting 1 - 10 and
press it down as far as the
stop. Ignition takes place au-
tomatically (ignition sparking
audible) until the flame ig-
nites.
Keep the control knob
pressed down for a further
10 seconds to allow the safe-
ty pilot to operate.
In the event of a
fault always wait
2 minutes before attemp-
ting to reignite!
If the flame goes out again,
re-ignition occurs immediate-
ly during the closing time of
the safety pilot (approx.
30 seconds).
If there is no flame, the auto-
matic ignitor continues to op-
erate until the control knob
(a) is switched to „0".
If there is air in the gas sup-
ply line, it can take up to two
minutes until there is gas
available for combustion.
During this time hold the
control knob down until the
flame lights.
3. To ensure even and rapid
warm air distribution as well
as lower surface tempera-
tures on the heating unit, we
recommend that you operate
the heater with a running -
Trumavent warm air system.
The Trumatic S 3002
and S 5002 heating sy-
stems (with automatic igni-
ters) can be fitted subse-
quently with a remote igniti-
on indicator (e - Art. No.
30040-65000) with no trouble
at all.

Room Thermostat

An average room tempera-
ture of about 22°C can be
achieved without blower
operation with a thermostat
setting of 3 - 5. For operation
with blower, we recom-
mend a thermostat setting of
4 - 8.
The exact thermostat setting
must be determined in each
case, depending on how
much heat is needed and the
design of your vehicle.
The thermostat probe is
underneath the heater.
.
a
Please note that the ther-
.
mostat will be adversely af-
.
fected by cold draughts from
refrigerator vents, gaps be-
low doors, etc., or by a deep-
piled carpet. Always be sure
to avoid problems of this
kind, otherwise satisfactory
temperature control cannot
be guaranteed.

Switching off

Turn the control switch to „0"
(the automatic ignition will
switch off at the same time).
If the unit is not used for a
relatively long period of time,
close off the quick-action
gate valve on the gas pipe
and gas bottle.
7