Panasonic WJ-HD309 Operating Instructions Manual page 113

Digital disk recorders
Hide thumbs Also See for WJ-HD309:
Table of Contents

Advertisement

G Baud Rate
Select the communication speed for data transmission with
a connected device from the following.
2 400/4 800/9 600/19 200/38 400 bps
G Data Bit
It is impossible to change the value for this setting.
8 bit
G Parity
Select a method to check a transmission error at communi-
cation from the following.
NONE: No parity check
EVEN: Even parity
ODD: Odd parity
G Stop Bit
Select a stop bit from the following.
1 bit/2 bit
G Retry Timing
Select a retransmission interval for when data reception is
not confirmed from the following.
OFF/100 ms/200 ms/400 ms/1 000 ms
G Alarm Data
Select a method to inform the connected controller of an
event occurrence from the following.
OFF: Does not function.
0 s: Informs the controller every time an event is detected.
1 s/5 s: Informs the controller when a specified time has
passed after detecting an event.
G Camera Number Setup
It is possible to assign a number to each camera channel to
operate cameras using the controller compatible with
PS·Data.
Do the following to assign numbers to the camera chan-
nels.
[Screenshot 1]
Start operation from the "PS·Data Setup" menu.
SETUP MENU
Maintenance
Recording
Switcher
Display
I
Unit Adress(System)
Camera Control
I
Unit Adress(Controller)
PS.DATA Setup
I
Cascade
RS485 Setup
I
Baud Rate
I
RS232C Setup
Data Bit
I
Parity
NW Setup 1
I
Stop Bit
NW Setup 2
I
Retry Timing
I
NTP Setup
Alarm Data
I
Camera Number Setup
z Move the cursor to "Camera Number Setup" using the
arrows button (C D) and press the SET button.
Event
Schedule
LIVE
Comm
System
001
001
OFF
9600
8
NONE
1
OFF
1s
SETUP
[Screenshot 2]
The "Camera Number Setup" pop-up window will be dis-
played.
SETUP MENU
Maintenance
Recording
Switcher
Display
I
I
Camera Number Setup
Unit Adress(System)
Camera Control
I
Unit Adress(Controller)
PS.DATA Setup
CAM PORT
CAM No.
I
Cascade
1
001
RS485 Setup
I
Baud Rate
2
I
002
RS232C Setup
Data Bit
I
3
Parity
003
NW Setup 1
I
Stop Bit
4
004
NW Setup 2
I
Retry Timing
5
005
NTP Setup
I
Alarm Data
6
006
I
Camera Number Setup
7
007
8
008
x Move the cursor to a desired "CAM No." of "CAM PORT"
using the arrows button.
[Screenshot 3]
The cursor will move to the selected "CAM No." of "CAM
PORT".
SETUP MENU
Maintenance
Recording
Switcher
Display
I
I
Camera Number Setup
Unit Adress(System)
Camera Control
I
Unit Adress(Controller)
PS.DATA Setup
CAM PORT
CAM No.
I
Cascade
1
001
RS485 Setup
I
Baud Rate
2
I
002
RS232C Setup
Data Bit
I
3
Parity
003
NW Setup 1
I
Stop Bit
4
004
NW Setup 2
I
Retry Timing
5
005
NTP Setup
I
Alarm Data
6
006
I
Camera Number Setup
7
007
8
008
c Select a camera number by rotating the jog dial.
Repeat steps 2 and 3 to assign camera numbers to the
other CAM PORT.
v Move the cursor to "OK" using the arrows button and
press the SET button.
→ Camera numbers will be assigned and the "Camera
Number Setup" menu will be closed.
Notes:
• When you move the cursor to "CANCEL" in step 4
and press the SET button, the settings will be can-
celed and the "Camera Number Setup" menu will be
closed.
• The assignment of camera numbers will not be
applied until the SET button is pressed after moving
the cursor to "OK" in step 4.
e
[RS485 Setup] Settings for RS485
Perform the following settings for RS485.
SETUP MENU
Maintenance
Recording
Switcher
Display
I
Baud Rate
Camera Control
I
Control Camera CH
PS.DATA Setup
I
Data Bit
RS485 Setup
I
Parity
I
RS232C Setup
Stop Bit
NW Setup 1
NW Setup 2
NTP Setup
Event
Schedule
LIVE
Comm
System
001
001
CAM PORT
CAM No.
OFF
9
009
9600
10
010
8
11
NONE
011
1
12
012
OFF
13
013
1s
14
014
SETUP
15
015
16
016
O K
CANCEL
Event
Schedule
LIVE
Comm
System
001
001
CAM PORT
CAM No.
OFF
9
009
9600
10
010
8
11
NONE
011
1
12
012
OFF
13
013
1s
14
014
SETUP
15
015
16
016
O K
CANCEL
Event
Schedule
LIVE
Comm
System
19200
SETUP
8
NONE
1
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-hd316