I [Maintenance] Functions For Maintaining - Panasonic WJ-HD309 Operating Instructions Manual

Digital disk recorders
Hide thumbs Also See for WJ-HD309:
Table of Contents

Advertisement

I [Maintenance] Functions for Maintaining

Perform the settings for the hard disk drives.
It is possible to check the histories (log) of event occur-
rence, error occurrence and access.
SET UP MENU
Maintenance
Recording
Switcher
Display
MANU
REC Rate Status
CAM 1
AUTO
Disk Info
CAM 2
AUTO
Version Info
CAM 3
AUTO
CAM 4
AUTO
Disk End Mode
CAM 5
AUTO
Disk Capacity
CAM 6
AUTO
CAM 7
AUTO
Date Delete
CAM 8
AUTO
CAM 9
AUTO
CAM 10
AUTO
CAM 11
AUTO
Event Log
CAM 12
AUTO
CAM 13
AUTO
Error Log
CAM 14
AUTO
Access Log
CAM 15
AUTO
CAM 16
AUTO
q
[REC Rate Status] Check the recording rate
and the image quality for each camera channel.
Recording rate for each recording mode for each cam-
era (as shown below) will be displayed in list form.
SET UP MENU
Maintenance
Recording
Switcher
Display
MANU
REC Rate Status
CAM 1
AUTO
Disk Info
CAM 2
AUTO
Version Info
CAM 3
AUTO
CAM 4
AUTO
Disk End Mode
CAM 5
AUTO
Disk Capacity
CAM 6
AUTO
CAM 7
AUTO
Date Delete
CAM 8
AUTO
CAM 9
AUTO
CAM 10
AUTO
CAM 11
AUTO
Event Log
CAM 12
AUTO
CAM 13
AUTO
Error Log
CAM 14
AUTO
Access Log
CAM 15
AUTO
CAM 16
AUTO
MANU: Manual recording
SCHE: Schedule recording
PRE EVT: Pre-event recording
POST EVT: Post-event recording
EMR: Emergency recording
w
[Disk Info] Check the available hard disk space
The available hard disk space of the following will be
displayed: The built-in hard disk (normal recording
area, event recording area and copy area), extension
unit (EXT1 - 7), DVD-RAM, CD-R and DVD-R disk drive
connected to the copy port (COPY1 or COPY2).
Refer to page 25 for more details on the built-in hard
disk.
It is also possible to perform the settings for the hour-
meter (the active time of the HDD) warning and for the
HDD safety mode with this menu.
SETUP MENU
Maintenance
Recording
Switcher
Display
1
REC Rate Status
160GB
160GB
MAIN
Disk Info
15000h
15000h
160GB
160GB
EXT7
Version Info
15000h
15000h
160GB
160GB
EXT6
Disk End Mode
15000h
15000h
160GB
160GB
EXT5
Disk Capacity
15000h
15000h
160GB
160GB
EXT4
Data Delete
15000h
15000h
160GB
160GB
EXT3
15000h
15000h
160GB
160GB
EXT2
15000h
15000h
Event Log
160GB
160GB
EXT1
15000h
15000h
Error Log
I
Warning for Disk Life Time
Access Log
I
HDD Safety Mode
Event
Schedule
LIVE
Comm
System
SCHE
PRE EVT
POST EVT
EMR
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
SUPER FINE
1ips
1ips
1ips
1ips
FINE
1ips
1ips
1ips
1ips
NORMAL
1ips
1ips
1ips
1ips
EXTENDED
1ips
1ips
1ips
1ips
Event
Schedule
LIVE
Comm
System
SCHE
PRE EVT
POST EVT
EMR
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
SUPER FINE
1ips
1ips
1ips
1ips
FINE
1ips
1ips
1ips
1ips
NORMAL
1ips
1ips
1ips
1ips
EXTENDED
1ips
1ips
1ips
1ips
Event
Schedule
LIVE
Comm
System
2
3
4
Remaining
Normal REC Area
1800GB
160GB
160GB
Event REC Area
1200GB
15000h
15000h
Copy Area
1000GB
160GB
160GB
1
Copy
(Rear)
1000GB
15000h
15000h
160GB
160GB
2
1000GB
Copy
(Front)
15000h
15000h
160GB
160GB
15000h
15000h
160GB
160GB
15000h
15000h
160GB
160GB
15000h
15000h
160GB
160GB
15000h
15000h
3000h
OFF
Note: The displayed available disk space on this menu
will not include the space required for data man-
agement. Therefore, the understated available disk
space will be displayed.
• Hour meter warning setting
Select the duration as the maximum active time of the
hard disk from the followings. Warning will be displayed
when the set time have passed.
10 000 h/20 000 h/30 000 h
• HDD safety mode
The HDDs will not start up with the default setting when
installing this unit in the rack without turning off the
power of the unit, to prevent malfunction caused by
shock or vibration.
After completing the installation, set the HDD SAFETY
MODE to OFF. Otherwise, the unit will be unable to
operate when turning the power on after a shutdown
caused by an unexpected incident such as a power
outage.
Refer to page 64 for further information.
e
[Version Info] Check the version information
Version information of the software and the hardware,
and the MAC address will be displayed.
SETUP MENU
Maintenance
Recording
Switcher
Display
REC Rate Status
I
Software
I
Hardware (M)
Disk Info
I
(V)
Version Info
I
Mac Address
Disk End Mode
Disk Capacity
Data Delete
Event Log
Error Log
Access Log
r
[Disk End Mode] Set actions to be taken when
the available hard disk space has run out
Select an action from the followings to be taken when
the available space of the built-in hard disk (normal
recording area, event recording area, copy area) or the
external recording device (DVD-RAM, CD-R or DVD-R
disk drive) connected to the copy port (COPY1,
COPY2) is running out.
SETUP MENU
Maintenance
Recording
Switcher
Display
I
HDD
REC Rate Status
Normal Recording Area
Disk Info
Event Recording Area
Version Info
COPY Area
I
COPY1
Disk End Mode
I
COPY2
Disk Capacity
Data Delete
Event Log
Error Log
Access Log
Event
Schedule
LIVE
Comm
System
V1.00
V1.00
V1.00
AA-BB-CC-DD-EE-FF
Event
Schedule
LIVE
Comm
System
CONTINUE
CONTINUE
STOP
STOP
STOP
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-hd316

Table of Contents