I [Comm] Settings For Communication With Other Devices - Panasonic WJ-HD309 Operating Instructions Manual

Digital disk recorders
Hide thumbs Also See for WJ-HD309:
Table of Contents

Advertisement

I [Comm] Settings for communication with other devices

It is necessary to adjust the communication speed and use
the same communication protocol with external devices
such as a controller when connecting those external
devices to the DATA port or the SERIAL connector
(RS232C).
It is also necessary to perform the settings for the network
such as the IP address and the gateway address when
operating this unit a PC via a network such as a LAN.
These are the descriptions of how to perform the required
settings for communication with external devices.
q
[Camera Control] Settings for the communica-
tion method and the cable compensation for
camera control
Select a communication method for each camera chan-
nel to control cameras from the following.
SETUP MENU
Camera Control
PS.Data Setup
RS485 Setup
RS232C Setup
NW Setup 1
NW Setup 2
NTP Setup
COAX: Controls camera with the coaxial communica-
tion (CAM 1 - 8 CH are available for the WJ-HD316,
CAM 1 - 6 CH are available for the WJ-HD309)
PSD: Controls camera with the PS·Data. (CAM 9 - 16
CH are available for the WJ-HD316, CAM 7 - 9 CH
are available for the WJ-HD309)
RS 485: Controls camera with the RS 485 communica-
tion. (CAM 1 - 16 CH are available for the WJ-
HD316, CAM 1 - 9 CH are available for the WJ-
HD309)
OFF: Does not control camera (CAM 1 - 16 CH are
available)
Notes:
• Perform settings according to the cameras connect-
ed to this unit.
• CAM 9-16 control 4 cameras each (only for the WJ-
HD316).
• When using the coaxial communication to control
cameras, connect cameras to the VIDEO IN con-
nectors 1 - 8 for the WJ-HD316 (1 - 6 for the WJ-
HD309) (coaxial communication compatible). When
controlling cameras connected to other VIDEO IN
connectors with coaxial communication, use a
coaxial communication unit (WJ-MP204). In this
case, select "PSD" for the communication method
for the camera channels to be controlled through
the coaxial communication unit.
112
Maintenance
Recording
Event
Schedule
LIVE
Switcher
Display
Comm
System
I
Type of Camera Control
CAM
COMP
TYPE
CAM
TYPE
CAM1
S
COAX
CAM9
CAM2
S
COAX
CAM10
PSD
CAM3
S
COAX
CAM11
CAM4
S
COAX
CAM12
CAM5
S
COAX
CAM13
CAM6
S
COAX
CAM14
RS485
CAM7
S
COAX
CAM15
CAM8
S
COAX
CAM16
• To prevent operation mistakes, set the unused cam-
era channels to off.
It is possible to compensate for the video signal
transmission loss from the camera when using the
VIDEO IN connector 1 - 8. (cable compensation)
Perform the settings for the cable compensation
according to the length of cable used.
S: When the length of cable used is shorter than
500 m
M: When the length of cable used is longer than
500 m and shorter than 900 m
L: When the length of cable used is longer than
900 m and shorter than 1 200 m
Notes:
• Use 5C-2V cables for the cable compensation.
• Perform the settings for the cable compensation
properly according to the cable length. Otherwise
camera pictures may not be displayed/recorded
correctly.
w
[PS.Data Setup] Settings for the PS·Data
Perform the following settings for the PS·Data.
SETUP MENU
Maintenance
Recording
Switcher
Display
I
Unit Adress(System)
Camera Control
I
Unit Adress(Controller)
PS.DATA Setup
I
Cascade
RS485 Setup
I
Baud Rate
I
RS232C Setup
Data Bit
I
Parity
NW Setup 1
I
Stop Bit
NW Setup 2
I
Retry Timing
I
NTP Setup
Alarm Data
I
Camera Number Setup
G Unit Address (System)
A unit address (System) is a unique number assigning to
PS·Data devices. The addresses must be unique to identify
system devices when connecting multiple devices compati-
ble with PS·Data. Numbers, "001"-"099", are to be assigned
as the unit addresses to the system devices.
G Unit Address (Controller)
The unit address (controller) is used to control a PS·Data
device connected to this unit. Numbers, "001" - "099" are to
be assigned.
G Cascade
Select ON or OFF whether or not to use the cascade con-
nection.
Set this to ON when connecting two or more units or in the
cascade connection.
ON: Select this when connecting units in the cascade con-
nection.
OFF: Does not function.
Event
Schedule
LIVE
Comm
System
001
001
OFF
9600
8
NONE
1
OFF
1s
SETUP

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-hd316

Table of Contents