CHAPTER 4 FRONT AND REAR PANEL CONTROLS

4.1 INTRODUCTION

TM
The Genesys Power Supply series has a full set of controls, indicators and connectors that allow
the user to easily setup and operate the unit. Before starting to operate the unit, please read the
following sections for explanation of the functions of the controls and connectors terminals.
- Section 4.2: Front panel controls and indicators.
- Section 4.3: Rear panel controls and connectors.

4.2 FRONT PANEL CONTROLS AND INDICATORS

See Fig.4-1 to review the controls, indicators and meters located on the power supply front panel.
POWER
19
Table 4-1: Front Panel controls and indicators
Number Control/Indicator
VOLTAGE control
1
2
VOLTAGE indicator
3
VOLTAGE display
AND CONNECTORS
2
3
1
VOLTAGE
DC VOLTS
FINE
PREV/
ALARM
16
18
17
15
Fig.4-1: Front panel controls and indicators
Description
High resolution rotary encoder for adjusting the Output
Voltage. Also adjusts the OVP/UVL levels and selects
the Address.
Green LED , lights for Constant-Voltage mode
operation.
4 digit, 7-segment LED display. Normally displays the
output voltage. When the PREV button is pressed, the
display indicates the programmed setting of the output
voltage. When the OVP/UVL button is pressed, the
Voltage display indicates the OVP/UVL setting.
4
OVP
FOLD
REM/LOC OUT
UVL
14
11
13
9
12
27
27
6
5
CURRENT
DC AMPS
7
8
10
Section
5.2.1
5.3.1
5.4.1
7.2.2